EasyManua.ls Logo

NEC Electra Elite IPK II System - Page 1137

NEC Electra Elite IPK II System
1190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electra Elite IPK II Document Revision 4C
Warning Tone For Long Conversation 2 - 1113
21-01-01 System Options for Outgoing Calls – Seizure Trunk Line Mode
Set the time the (0~64800 seconds) system should wait before starting the Warning Tone Timer.
(default: 0)
21-01-03 System Options for Outgoing Calls – Trunk Interdigit Time (External)
Set the time (0~64800 seconds) the system waits to expire before putting a call in talk state.
(default: 5)
25-07-07 System Timers for VRS/DISA – Conversation Warning Tone Time
Set the time (0~64800 seconds) the system should wait before the Warning Tone is heard by
DISA callers . If an outside call is transferred or forwarded off-premise using an outside trunk,
this time starts immediately. This occurs if either trunk involved in the call is programmed for the
Warning Tone (Program 14-01-17).
(default: 3600)
25-07-08 System Timers for VRS/DISA – Long Conversation Disconnect
Set the time (0~64800) after the Warning Tone is heard the system waits before disconnecting
DISA calls – unless the Continue code is entered (Program 20-28-01).
(default: 10)
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward System Access (DISA)
Intercom
Long Conversation Cutoff
Single Line Telephones, Analog 500/2500 Sets

Table of Contents

Related product manuals