Electra Elite IPK II Document Revision 4C
ISDN Compatibility 2 - 645
22-11-02 Translation Number Conversion – Target Number
For each DID Translation Table entry (1~2000), specify the extension the system dials after
translation (24 digits maximum).
22-09-01 DID Basic Data Setup – Expected Number of Digits
For each DID Translation Table (1~20), enter the number of digits the table expects to receive
from the CO (eight maximum). For example, for a table used with 3-digit DID service, enter 3.
For additional DID Services refer to Direct Inward Dialing (DID) on page 2-321.
Calling Party Number Presentation for either ISDN – BRI or PRI
Calling Line Identification Presentation (CLIP)
10-03-05 ETU Setup (for PRI PKG Setup) – CLIP Information Announcement
Based on this setting, the system includes a Presentation Allowed (1) or Presentation Restricted
(0) in the Setup message to allow or deny the Calling Party Number. Program 15-01-04 must
also be set to 1 if this option is enabled.
21-12-01 ISDN Calling Party Number Setup for Trunks
Assign Calling Party Numbers for each trunk (maximum 16 digits per entry). When a call is made
by an extension which does not have an Extension Calling Number assigned (Program 21-13),
the system sends the calling number for the ISDN trunk defined in 21-12. If the Calling Party
Number is assigned in both Program 21-12 and Program 21-13, the system sends the data in
Program 21-13.
Calling Party Number Presentation from Station
10-03-05 ETU Setup (for PRI PKG Setup) – CLIP Information Announcement
Based on this setting, the system includes a Presentation Allowed (1) or Presentation Restricted
(0) in the Setup message to allow/deny the Calling Party Number. Program 15-01-04 must also
be set to 1 if this option is enabled.
15-01-04 Basic Extension Data Setup – ISDN Caller ID
If both PRG 15-01-04 and PRG 10-03-05 are enabled (1), the system includes Caller ID in the
Setup message as Presentation Allowed. If these options are disabled (0), it is Presentation
Restricted.
20-06-01 Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
20-08-13 Class of Service Options (Outgoing Call Service) – ISDN CLIP
Determine if the ISDN calling line identity presentation and screening indicators are allowed:
0 = Disabled (Default)