Electra Elite IPK II Document Revision 4C
Multimedia Conference Bridge 2 - 721
The CNF(16)-U20 ETU is a standalone Conference Bridge that cannot be linked with
another CNF ETU to increase the number of conferences.
Conference ports should be placed in a Class of Service (COS) with no enabled alert tones.
In Simple Mode, the call duration time starts when the last person joins the conference.
A scheduled conference with nine or more participants automatically disables the
participant announce feature.
In Simple Mode, all participants have the same conference password. Default passwords
are:
Conference 1 111111
Conference 2 222222
Conference 3 333333
Conference 4 444444
If password is entered before the prompt finishes speaking, the first digit is not recognized.
Enter password after the prompt is completed to prevent failed password entry.
Custom Greeting is automatically enabled after the user accepts the newly recorded
greeting.
Entry or Exit announcement can be disabled during conference setup per conference.
Participants are not requested to record name when Entry/Exit announcement is disabled.
All passwords must have six digits.
In Simple Mode, only the number of conferences, duration, password, and participant
announce can be edited from the web browser interface.
Edit options do not take effect until the conference is idle.
When adding a CNF(16)-U20 ETU to a KSU, the slot must be assigned to match SW1
setting on the ETU or it does not initialize.
A comparison between simple and advanced mode is shown below:
DID calls to a Multimedia Conference Bridge Department Group Pilot are not answered if
Pre-Ringing is enabled.
Feature Simple Mode Advanced Mode
Passwords Per Conference Per Participant
Number of Participants Fixed, depending on
CNF(16)-U20 ETU
configuration
Selected by conference originator. From
one to 15 participants can be
accommodated.
E-Mail Notification N/A Selected by originator per conference.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Electra Elite IPK II System and is the answer not in the manual?

NEC Electra Elite IPK II System Specifications

General IconGeneral
BrandNEC
ModelElectra Elite IPK II System
CategoryTelephone System
LanguageEnglish

Related product manuals