EXAMPLE DC3,1,3,5,0,1 | Param. #1: Acquire analog data on an external trigger
| Param. #2: No consequence for this data acquisition mode
| Param. #3: Acquire analog channels 1 & 2 (3
10
= (11)
2
)
| Param. #4: Acquire feedback channels 1 & 3 (5
10
= (101)
2
)
| Param. #5: No consequence for this data acquisition mode
| Param. #6: Acquire one sample of data
ES 1MF | Turn OFF motor #1 when the external event trigger occurs
DE1 | Enable analog data acquisition
DD | Query data-acquisition done status
1 = true, 0 = false.
If true,
DE0 | Disable trace variable data acquisition
DG | Get data collected
Section 3 – Remote Mode 3-57