EO  automatic execution on power on 
 
   IMM PGM MIP 
USAGE  ♦      ♦ 
 
SYNTAX     xxEOnn  or  xxEO? 
 
PARAMETERS    
Description   xx  [ int ]        -  program number 
 nn  [ int ]        - number of times of execution  
Range        xx   -  1   to   100 
nn   -  1   to   2e9 
Units        xx   -  none 
nn   -  none
 
Defaults   None 
 
DESCRIPTION  This command sets the program number that is automatically executed on power 
on.  If nn is missing, the xx numbered program is executed once. 
 
RETURNS  If the sign “?” takes place of nn value, this command reports the number of the 
program that is executed on power on and the number of times of execution. 
 
REL. COMMANDS    QP  -   quit programming mode 
 EX  -    execute stored program   
 AP  -    abort stored program execution 
    XX -   erase program 
 
 
EXAMPLE   3EO  |  set program #3 to be executed once on power on 
    EO?  |  query the program number executed on power on 
 EO,3,1  |  controller returns program #3 executed once on power on 
 EO |  Reset automatic program execution – no program is  
   executed on power on 
3-54          Section 3 – Remote Mode