EO automatic execution on power on
IMM PGM MIP
USAGE ♦ ♦
SYNTAX xxEOnn or xxEO?
PARAMETERS
Description xx [ int ] - program number
nn [ int ] - number of times of execution
Range xx - 1 to 100
nn - 1 to 2e9
Units xx - none
nn - none
Defaults None
DESCRIPTION This command sets the program number that is automatically executed on power
on. If nn is missing, the xx numbered program is executed once.
RETURNS If the sign “?” takes place of nn value, this command reports the number of the
program that is executed on power on and the number of times of execution.
REL. COMMANDS QP - quit programming mode
EX - execute stored program
AP - abort stored program execution
XX - erase program
EXAMPLE 3EO | set program #3 to be executed once on power on
EO? | query the program number executed on power on
EO,3,1 | controller returns program #3 executed once on power on
EO | Reset automatic program execution – no program is
executed on power on
3-54 Section 3 – Remote Mode