Nordson ProBlue Flex - Clock;Scheduler; Communications; NordNet Masters (two available); Remote Color Touchscreen (if used)

Nordson ProBlue Flex
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
6-5
Part 1128350_02
E 2020 Nordson Corporation
USB
S Check e xternal connection at LVC X13
S Check LVC DS14 status
Clock/Scheduler
S Check that coin cell battery is installed on BT1 on LVC
S Check battery voltage
S Check that this feature is enabled
Communications
NordNet Masters (two available)
S Check connections to X9 and X10
S Check associated power LEDs (DS9 and DS11)
S Check associated data Tx/RxLEDs(DS8andDS10)
Ethernet (if used)
S X14, X15, X16, X17
- Check for LED activity on the RJ-45 connectors
Fieldbus Module (if present)
S Check that the module is seated at LVC X1
S Check the wiring connection to the module
Wireless Module (if present)
S Check that the module is seated at LVC X8
S Check that DS4 is on
S Check f or presence of access point using a phone or tablet
Remote Color Touchscreen (if used)
S Check Ethe rnet cable at LVC and at remote touchscreen
S Check that screen backlight is on
S Check that a color graphic screen appears
Software
S EnsuremicroSDcardispresentandsecureinitssocket(X11)
S Check any daughter cards attached to the LVC
S Check green power LEDs on LVC (DS6, DS13, DS15). Red or Off
indicates a problem.