Calculating Melter Power Requirements
A-1
Part 1128350_02
E 2020 Nordson Corporation
Appendix A
Calculating Melter Power Requirements
Before locating the melter on the production floor or attaching hoses and
applicators to the melter, you must calculate the electrical power required by
the hoses and applicators and confirm that the required power does not
exceed maximum allowable wattages. Properly calculating melter power
requirements will prevent damage to the melter and identify the maximum
allowabledistancebetweenthemelter and the point at which the hot melt is
dispensed.
The following three maximum wattages must be considered when calculating
the power required by the hoses and applicators.
S Single-component maximum—The wattage of any single hose or
applicator
S Hose/applicator pair maximum—The wattage of any hose and
applicator (hose/applicator pair)
S Hose/applicator module maximum—The wattage of any two hoses
and two applicators (two hose/applicator pairs)
If your Nordson representative has already calculated the hose/applicator
power requirements and confirmed that the maximum allowable wattages will
not be exceeded, then no further calculation is necessary. However, you
should re-evaluate the hose and applicator power requirements before you:
S add a ne w hose or applicator to the melter that was not factored into
the original wattage evaluation
S replace an existing hose with a longer hose or an existing applicator
with a larger applicator