EasyManua.ls Logo

Nordson ProBlue Flex - I;O Declarations on the ATS Board

Nordson ProBlue Flex
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adhesive Tracking System
D-8
Part 1128350_02
E 2020 Nordson Corporation
I/O Declarations on the ATS Board
SeeFigureD-1fortheATSboard.
Connector Terminals Type Rating Use
X2, X4 1-8
Standard
RJ45
Ethernet
10/100
Ethernet
TB1, T B2
1 24VDC
Input/Output
24VDC @
650 mA
Used to supply 24VDC to the ATS board. Two identical
connectors provided so power can be daisy-chained to
other expansion boards.
TB3 1, 4 Inductive
sensor
inputs
3.3V logic The inductive sensor attached completes an RLC
oscillator. The frequency shifts slightly when a flow meter
gear tooth passes by the sensor.
TB3 2, 3, 5, 6 Circuit
Common
Circuit
Common
TB4 1 24VDC
Output
24 VDC @
100 mA
TB4 2 Analog
input signal
0-10V;
4-20 mA
Line speed input signal provided by customer.
TB4 3, 4 Circuit
Common
Circuit
Common
TB5 1 24VDC
Output
24 VDC @
200 mA
24VDC provided to power external encoder device.
TB5 2, 3, 4, 5 Encoder
signals
24VDC
logic
Inputs for quadrature, differential encoder signals.
TB5 7, 8 Circuit
Common
Circuit
Common
TB6 1 Ejector 24V
output
24VDC @
300 mA
Ejector output used by customer to signal bad products
TB6 2, 5, 6, 9, 10 Circuit
Common
Circuit
Common
TB6 3, 7 24VDC
Output
24 VDC @
100 mA
24VDC provided to power external photosensor device.
TB6 4, 8 Trigger
inputs
24VDC
logic
Input for photosensor signal. Can support NPN (sinking)
or PNP (sourcing) signals.

Table of Contents