Technical Data
7-4
Part 1128350_02
E 2020 Nordson Corporation
Electrical Specifications
Item Data
Electrical service
200 to 240 VAC 1Ø or 3Ø 50/60 Hz
200 to 240 VAC 1Ø N/PE 50/60 Hz
400/230 VAC 3Ø N/PE 50/60 Hz
With optional transformer 400 to 480 VAC 3Ø 50/60 Hz
Input voltage tolerance +10%, -15%
Melter Power Requirements
CAUTION! The following tables are specific to melters without transformers.
Melters using optional transformers are limited to 3 kVA for external
hose/applicators.
The ProBlue Flex 400/480 volt melte r transformer assembly is shipped
separately. R efer to ProBlue Flex 400/480 Volt Transformer (Appendix F) for
installation instructions, parts information, and wiring details.
4 Kg Tank (T04, X04)
Y
37
N/A
24
30
36
20
N/A
Voltage (VAC)
2H/A
Legacy
Fast Warm Up
Maximum Amperage
4 H/A 6 H/A 8 H/A 4 H/A 6 H/A
200-240, 1-phase
200-240, 3-phase
400-230, 1-phase
400-230, 3-phase
19
13
18
10
28
21
27
14
N/A
28
N/A
18
14
35
22
34
14
8H/A
N/A
N/A
34
20
2H/A
26
19
25
11