Technical Data
7-1
Part 1128350_02
E 2020 Nordson Corporation
Section 7
Technical Data
General Specifications
Item Data
Type of system Non-circulating tank
Filter Type Inside-out disposable
Viscosity:
Range 800 - 10,000 cP
Range with reduced performance 10,000 - 30,000 cP
Temperature range:
Melt section 40 to 204°C (100 to 400 °F)
Hose and Applicators 40 to 230°C (100 to 450 °F)
Ambient temperature range -5 to 50°C (23 to 122 °F)
Temperature control stability ±0.5°C (1°F)
NOTE: Built-in automatic
tuning of PID c ontrol available, if
needed).
Hose ports (hydraulic) 9
Hose/Applicator power:
Number of pairs per power module 2
Number of H/A pairs 2, 4, or 6
Maximum power per power module 2000 W
Maximum power per pair 1200 W
Minimum power per channel 1000 W
Ingress Protection (IP) rating IP54
Noise 64 dB (A) at maximum pump
speed