Troubleshooting
6-23
Part 1128350_02
E 2020 Nordson Corporation
1
2
3
Figure 6-6 Accessing components
1. RTD
2. Thermostat
3. Level sensor location (inside
the tank)
SeeFigure6-6.
4. To remove the RTD:
Loosen the two screws that secure the retaining plate, and then slide the
RTD out from under it.
5. To remove the thermostat:
Remove the rubber boot, disconnect the wires, and then remove the two
screws.
6. To remove the level sensor:
Remove the four or six retaining nuts, and then remove the level sensor
andgasketfrominsidethetank.