Installation
3-24
Part 1128350_02
E 2020 Nordson Corporation
Connecting Power Cables (contd)
Table 3-3 Electrical Service Information
Use Electrical Connector
Terminals..
Use Voltage Plug
If the Electrical Service Type is..
L1 L2 L3 N
400/230VAC 3-phase
(4-wire service, including a
neutral) See note.
3/N/PE AC
400/230V
1126605
230VAC 1-phase
(2-wire service, including a
neutral) See note.
1/N/PE AC
200–240V
1126607
200 to 240VAC 3-phase
(3-wire service without a
neutral)
3/PE AC
200–240V
1126604
200 to 240VAC 1-phase
(2-wire service without a
neutral)
1/PE AC
200–240V
1126606
400/230VAC 3-phase service
Includes the 415/240VAC 3-phase voltage
(4-wire service including neutral)
230VAC 1-phase service
Includes the 240VAC 1-phase voltage
(2-wire service, including neutral)