Oki Data CONFIDENTIAL
45762101TH Rev.1
3-12
3. MAINTENANCE MENUS
LEVEL0
(1) How to select the menu items
Menu items can be selected by pressing of [4] or [
], or by pressing of [2] or [8].
Menu items can be entered by pressing of [6] or [4], and can be selected by pressing of [2] or [8].
XXXX
XXXX
Respective voltages
display during print
Transfer (TR) voltage (1)
Transfer (TR) voltage (2)
Charge (CH) voltage
Supply (SB) voltage
Develop (DB) voltage
Environment level
Develop (SB) voltage
(Front and back)
Transfer (TR) voltage (3)
Toner sensor monitor
K toner sensor status
monitor display
Toner pulse count
monitor
Toner pulse count
status monitor display
Toner TAG noise test
monitor
Tag serial No
(Last four digits)
Noise detection count
display.
Error detection count
display.
Motor controls
evaluation function
Main motor constant
speed timer value,
Environment
temperature
Fuser motor
constant speed timer
value, Fuse target
temperature
[2]
[8]
[4] [ ]
Engine status display
Heater information
Environment
information
Fuser,
CH, DB
Setup table number
TR
Setup table number
TR off
Setup table number
Error details
Error code display and
others
[2]
[8]
[2]
[8]
[2]
[8]

Table of Contents