4.REPLACEMENT OF PARTS
4.2.21 Guide Eject Lower Assy
(1) Remove the Scanner unit. (Refer to 4.2.8)
(2) Remove the Cover Assy Rear. (Refer to 4.2.20)
(3) Remove the Cover-Eject. (Refer to 4.2.16)
(4) Remove two screws (Silver : 8mm)
. Remove the Cover-Cassette-Rear
Assy
and Guide-Eject-Lower-Assy
.
(5) Remove the post
. Remove the Separator-SB-FD
and Spring-
Separator_SB
.
(6) Remove the Lever-Exit-Sensor
and Spring-Sensor-Exit
.
(7) Remove the Exit-Sensor
.
(8) Installing is performed by the inverse procedure with removing.
Note!
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
2. Install Cover-Cassette-Rear Assy
carefully to avoid the FFC cable