Oki Data CONFIDENTIAL
45762101TH Rev.1
2-40
2. TROUBLESHOOTING PROCEDURES
(2-3) Abnormal odor
Confirmation Items Confirmation Tasks Action at NG
(2-3-1) Locate the position with abnormal odor occurred.
Fuser unit Take out the fuser and confirm
the odor.
Perform (2-3-2).
Low-voltage power supply
unit
Take out the low-voltage power
supply unit and confirm the odor.
Exchange low-voltage
power supply unit
(2-4) Slow starting time
Confirmation Items Confirmation Tasks Action at NG
(2-4-1) Check a fuser unit
Halogen lamp Confirm the wattage of the
halogen lamp mounted in the
fuser.
Exchange for wattage
parts of the rated
voltage.
(2-4-2) Check optional parts
Expansion memory Reset the optional parts
(expansion memory) and recheck
the operation.
Exchange optional parts