EasyManua.ls Logo

Oki MB472w - Page 111

Oki MB472w
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Oki Data CONFIDENTIAL
45762101TH Rev.1
3-21
3. MAINTENANCE MENUS
Displays are switched by pressing the [2] key.
KR=*.**
KR : BLACK transfer roller resistance value [unit: uA]
• Displays are switched by pressing the [2] key.
ETMP=***UTMP=***
ETMP : Environment temperature [unit: DEC]
UTMP : Fuse target temperature [unit: DEC]
Displays are switched by pressing the [2] key.
DB:k**
DB : Develop voltage setting table ID number [unit: HEX]
Displays are switched by pressing the [2] key.
TR1:k**
TR2:k**
TRl : Transfer voltage parameter VTR1 table ID number [unit: HEX]
TR2 : Transfer voltage parameter VTR2 table ID number [unit: HEX]
Displays are switched by pressing the [2] key.
TROFF:**
TROFF : Transfer OFF voltage setting table ID number [unit: HEX]
5. Repeat steps 2 to 4 as required.
6. Pressing the [#] key terminates the test. (Returns to the status of step 1.)