EasyManua.ls Logo

Omron JX - Page 159

Omron JX
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-81
4-2 Function Mode
4
Functions
103Dh
Multi-step speed
reference 10
A030 R/W
0.0/Starting frequency to 4000
0.1 [Hz]
103Fh
Multi-step speed
reference 11
A031 R/W
1041h
Multi-step speed
reference 12
A032 R/W
1043h
Multi-step speed
reference 13
A033 R/W
1045h
Multi-step speed
reference 14
A034 R/W
1047h
Multi-step speed
reference 15
A035 R/W
1048h Jogging frequency A038 R/W 0 to 999 0.01 [Hz]
1049h Jogging stop selection A039 R/W
00: Free-run stop
01: Deceleration stop
02: DC injection braking stop
104Ah Torque boost selection A041 R/W
00: Manual torque boost only
01: Simple torque boost
1510h 2nd torque boost selection A241 R/W
104Bh Manual torque boost voltage A042 R/W
0 to 200 0.1 [%]
1511h
2nd manual torque boost
voltage
A242 R/W
104Ch
Manual torque boost
frequency
A043 R/W
0 to 500 0.1 [%]
1512h
2nd manual torque boost
frequency
A243 R/W
104Dh V/f characteristics selection A044 R/W
00: VC
01: 1.7th power of VP
06: Special VP
1513h
2nd V/f characteristics
selection
A244 R/W
104Eh Output voltage gain A045 R/W
20 to 100 1. [%]
1514h 2nd output voltage gain A245 R/W
1051h
DC injection braking
selection
A051 R/W
00: Disabled
01: Enabled during stop
02: Output frequency<A052 DB
1052h
DC injection braking
frequency
A052 R/W 0 to 600 0.1 [Hz]
1053h
DC injection braking delay
time
A053 R/W 0 to 50 0.1 [s]
1054h DC injection braking power A054 R/W 0 to 100 1. [%]
1055h DC injection braking time A055 R/W 0 to 600 0.1 [s]
1056h
DC injection braking method
selection
A056 R/W
00: Edge operation
01: Level operation
105Ah Frequency upper limit A061 R/W
0.0/Frequency lower limit
: A062 x 10 to Maximum frequency
: A004 x 10
0.1 [Hz]
1517h 2nd frequency upper limit A261 R/W
0.0/2nd frequency lower limit
: A262 x 10 to 2nd max. frequency
: A204 x 10
0.1 [Hz]
105Bh Frequency lower limit A062 R/W
0.0/Starting frequency
: b082 × 10 to Frequency upper limit
: A061 × 10
0.1 [Hz]
1518h 2nd frequency lower limit A262 R/W
0.0/Starting frequency
: b082 x 10 to 2nd frequency upper limit
: A261x10
0.1 [Hz]
Register
No.
Function name
Parameter
No.
R/W
Function
Monitor or data range
Resolution

Table of Contents