Analog input
A005 O/OI selection
02: Switches between O/FREQ adjuster via
terminal AT
03: Switches between OI/FREQ adjuster via
terminal AT
04: O input only
05: OI input only
02 No ⎯
A011 O start frequency 0.0 to Max. frequency 0.0 No Hz
A012 O end frequency 0.0 to Max. frequency 0.0 No Hz
A013 O start ratio 0. to 100. 0. No %
A014 O end ratio 0. to 100. 100. No %
A015 O start selection
00: External start frequency (A011 set value)
01: 0 Hz
01 No ⎯
A016 O, OI sampling 1. to 17. 8. No ⎯
Multi-step speed, Jogging
A020
Multi-step speed
reference 0
0.0/Starting frequency to Max. frequency 6.0 Yes Hz
A220
*2nd multi-step
speed reference 0
0.0/Starting frequency to 2nd max. frequency 6.0 Yes Hz
Parameter
No.
Function name
Monitor or data range
(Digital Operator)
Default
setting
Changes
during
operation
Unit
Set
value
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.