1066
Network Instructions Section 3-25
3-25-6 EXPLICIT MESSAGE SEND: EXPLT(720)
Purpose Sends an explicit message with any service code.
This instruction is supported by only CS/CJ-series CPU Unit Ver. 2.0 or later.
Ladder Symbol
Variations
Applicable Program Areas
@CMND
D00006
D00100
D00000
A34313000000 A20207
S
D
C
15 8 7 0
221
5
800
0
000
0
435
312
202
202
2E2
202
000
5C4
4D5
4F4
S: D00006
S+1: D00007
S+2: D00008
S+3: D00009
S+4: D00010
S+5: D00011
S+6: D00012
S+7: D00013
S+8: D00014
S+9: D00015
S+10: D00016
S+11: D00017
S+12: D00018
3
0
0
0
0
0
6
F
2
E
15 8 7 0
001A
0004
0000
0000
070
0
0000
S: D00000
S+1: D00001
S+2: D00002
S+3: D00003
S+4: D00004
S+5: D00005
Communications
Port Enabled Flag
for port 7
File Memory
Operation Flag
Command code: 2215 Hex (CREATE/DELETE DIRECTORY)
Parameter: 0000 Hex (create directory)
Disk No.: 8000 Hex (Memory Card)
Subdirectory name: CS1@@@@@. @@@ (@= space)
Directory name length: 0006 (6 characters)
Absolute directory path: \OMRON
Bytes of command data: 001A (26 decimal)
Bytes of response data: 0004 (4)
Destination network address: 00 Hex (local network)
Destination unit address: 00 Hex, Destination node number: 00 Hex (CPU Unit at local node)
Response requested, port number 7, 0 retries
Response monitoring time: 0000 Hex (2 seconds)
EXPLT(720)
S
D
C
S: First word of send message
D: First word of received message
C: First control word
Variations Executed Each Cycle for ON Condition EXPLT(720)
Executed Once for Upward Differentiation @EXPLT(720)
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification Not supported
Block program areas Step program areas Subroutines Interrupt tasks
OK OK OK OK