1230
Text String Processing Instructions Section 3-33
Description RGHT$(653) reads the number of characters designated by S2, from the left
(the beginning) of the first word of the text string designated by S1 until the
NUL code (00 hex), and outputs the result to D (with NUL added at the end).
If the number of characters to be read exceeds the number of characters des-
ignated by S1, the entire S1 text string will be output.
If 0 (0000 hex) is designated as the number of characters to be read, the two
NUL characters (0000 hex) will be output to D.
Note RGHT$(653) can be processed in the background. Refer to the SYSMAC CS/
CJ/NSJ Series PLC Programming Manual (W394) for details.
Flags
Precautions The maximum number of characters to be read that can be designated by S2
is 4,095 (0FFF hex). If more than that are designated, an error will be gener-
ated and the Error Flag will turn ON.
If 0000 (hex) is output to D, the Equals Flag will turn ON.
Example In this example, RGHT$(653) is used to read four characters.
3-33-6 GET STRING MIDDLE: MID$(654)
Purpose Reads a designated number of characters from any position in the middle of a
text string.
Ladder Symbol
Name Label Operation
Error Flag ER ON if more than 4,095 characters are designated by S1.
ON if more than 4,095 characters (0FFF hex) are desig-
nated by S2.
ON if the Communications Port Enabled Flag for the com-
munications port number specified as the Com Port num-
ber for Background Execution is OFF when background
processing is specified.
OFF in all other cases.
Equals Flag = ON if 0000 (hex) is output to D.
OFF in all other cases.
S1:
D:
S2: D00200
Text string CDEF
Four characters
(bytes) read.
Text string ABCDEF
MID$(654)
S1
S2
S3
D
S1: Text string first word
S2: Number of characters
S3: Beginning position
D: First destination word

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 and is the answer not in the manual?

Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CJ - REFERENCE MANUAL 08-2008
CategoryController
LanguageEnglish

Related product manuals