Text String Processing Instructions Section 3-33
The maximum number of characters to be read that can be designated by S2
is 4,095 (0FFF hex). If more than that are designated, an error will be gener-
ated and the Error Flag will turn ON.
If 0 (0000 hex) is designated as the number of characters to be read, the two
NUL characters (0000 hex) will be output to D.
If 0000 (hex) is output to D, the Equals Flag will turn ON.
Example In this example, MID$(654) is used to read three characters.
3-33-7 FIND IN STRING: FIND$(660)
Purpose Finds a designated text string from within a text string.
Ladder Symbol
Variations
Applicable Program Areas
Operands S1: Source Text String
S2: Found Text String
S1:
S3:
D: D00300
S2: D00200
S3: D00400
Text string ABCDEFGHIJ
Three characters read.
From 5th character
(leftmost byte in D00102).
Text string EFG
FIND$(660)
S1
S2
D
S1: Source text string first word
S2: Found text string first word
D: First destination word
Variations Executed Each Cycle for ON Condition FIND$(660)
Executed Once for Upward Differentiation @FIND$(660)
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification Not supported
Block program areas Step program areas Subroutines Interrupt tasks
OK OK OK OK
15 0
S1
to
Text string data: 4,095 characters max. + NUL
S1 + maximum 2,047 words
15 0
S2
to
Text string data: 4,095 characters max. + NUL
S2 + maximum 2,047 words