Subroutines Section 3-19
The step instructions, STEP(008) and SNXT(009) cannot be used in subrou-
tines.
Example When CIO 000000 is ON in the following example, subroutine 10 is executed
and program execution returns to the next instruction after the SBS(091) or
MCRO(099) instruction that called the subroutine.
OK
Task 2
Task 1 Task
Not allowed
Not allowed
OR
#10
#10
#10
Subroutine 10