Verify a DIMM
Servicing DIMMs 83
Watch the POST output for possible fault messages. The following output indicates that
POST did not detect any faults:
-> start /HOST/console
...
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
Note - The server might boot automatically at this point. If so, go directly to Step 4e. If it
remains at the ok prompt go to Step 4d.
d.
If the server remains at the ok prompt, type boot.
e.
Return the virtual keyswitch to normal mode.
-> set /System/keyswitch_state=normal
Set ???ketswitch_state' to ???normal'
f.
Switch to the system console and type the Oracle Solaris OS fmadm faulty
command.
# fmadm faulty
If any faults are reported, refer to the diagnostics instructions described in “Check for
Faults” on page 38.
5.
Switch to the Oracle ILOM command shell.
6.
Run the show faulty command.
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/PM0/CMP0/BOB0/CH1/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |