62 - ENGLISH
When [SDI MODE] is set to [OUTPUT]: 50 m (164'1") (When L-5.5CUHD is used, the cable length should be 90 m (295'3").)
f When the [DISPLAY OPTION] menu [SLOT IN] [SDI MODE] is set to [OUTPUT], attach a terminating resistor (75 Ω) to the terminal
with no device connected as an output destination.
f Use the BNC connector that is compatible with the coaxial cable and type of the signal to be used.
f Setting the [DISPLAY OPTION] menu [SLOT IN] is required depending on the connected external device or the input signal.
f Setting the [DISPLAY OPTION] menu [SLOT IN] [SDI LINK] is required when the dual link signal is input.
f To input the dual link signal, use the cable with same length and same type for connecting to the <SDI 1 IN> terminal and the <SDI 3 IN>
terminal. The image may not be projected correctly when the difference of the cable length is 4 m (13'1") or more.
f Directly connect the projector with the external device that will output the signal without going through a distributor, etc., when inputting dual
link signals. A phase difference is generated between the Link A signal and the Link B signal, and the image may not be projected correctly.
f An error in signal detection may occur when an unsteady signal is input to the projector. In such case, set the [DISPLAY OPTION] menu
[SLOT IN] to the content corresponding to the input signal.
f The <SDI 2 IN/1 OUT> terminal and the <SDI 4 IN/3 OUT> terminal do not support the input of the 6G-SDI signal or the 12G-SDI signal.
f To use the <SDI 2 IN/1 OUT> terminal or the <SDI 4 IN/3 OUT> terminal as an output terminal, set the [DISPLAY OPTION] menu [SLOT
IN] [SDI MODE] to [OUTPUT].
For <SDI OPT 1 IN>/<SDI OPT 2 IN> terminals of the Interface Board
This is an example when the optional Interface Board for 12G-SDI Optical (Model No.: ET-MDNFB10) is installed
in <SLOT>.
HD-SDI signal, 3G-SDI signal, 6G-SDI signal, or 12G-SDI signal
SDI - optical converter
Optical fiber cable
12G-SDI signal output compatible device
Note
f Prepare the commercially available SFP module and the optical ber cable required for connection according to the usage, video signal to
be input, specication of the external device to be connected, etc.
f The transmission distance may become shorter and the image may not display correctly when there is dust on the connector of the SFP
module or optical ber cable, or it is dirty. Attach the protection cap or cover supplied by each product to the connector of the SFP module or
the optical ber cable if the optical ber cable is not connected.