No. SX-DSV02310 - 8 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
2-6 COM LED, LINK LED and RTEX communication state
The t
able below shows display state of COM LED and LINK LED and RTEX communication status.
COM LED
Description
Pr.7.23 bit 4 = 0 Pr.7.23 bit 4 = 1
State
RTEX
communication
state
MNM1221 state
*1)
Communication
and servo are
Synced
MNM1221 state
*1)
Communication
and servo are
Synced
OFF Not established • INITIAL • INITIAL Not established
Flashing Green
Under
configuring
• RING_
CONFIG
• READY
• RING_
CONFIG
• READY
• RUNNING
Not established
Solid Green Established RUNNING
Not dependent
• RUNNING Not established
Flashing Red Clearable alarm relating to RTEX communication has occurred.
Solid Red Non-clearable alarm relating to RTEX communication has occurred.
*1) MNM1221 is an ASIC developed to control RTEX communication.
LINK LED
State Description
OFF
Non-connecting
(No power entry of transmitter node, or cable disconnection)
Solid Green
Proper connecting
(“TX” of transmitter node and own “RX” is electrically connected)
If RTEX communication related alarm occurs while non-RTEX alarm (e.g. Err. 16.0) has occurred, COM LED shows
the new alarm by lighting or flashing in red as described above.
Note that the 7-seg LED still displays the non-RTEX related alarm.
Upon power up or upon issuing of the reset command, LINK LED will blink once. This is normal because the LED is
initialized by the servo driver.
Lighting condition of COM LED can be changed by the setting of bit 4 of Pr.7.23 (RTEX function expansion setup 2).