No. SX-DSV02310 - 156 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
8-1-5 RTEX synchronization and initialization error protection (Err. 84.3)
Th
is alarm occurs when the initialization process fails to establish synchronization between the communication and
servo driver.
Cause The initialization process fails to synchronize the communication and servo
driver.
Detecting timing On power up of servo driver control power.
Upon restarting by the reset command.
Internal process upon
detecting error
Fails to establish RTEX communication (aborts due to incomplete initialization)
RTEX communication status is still in INITIAL condition (transition).
Action Replace the servo driver if the cause is not removed after turning on control
power.
Alarm clear attribute Cannot be cleared.
Display on COM LED Lighting in red