No. SX-DSV02310 - 15 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
3-3-2 Non-cyclic status flag
Byte 9
, bits 74 in the response show the status of the non-cyclic command, if the command is not a normal one (0h).
Bit Title Description
7 ERR Set to 1 when error occurs during process after reception of the command.
6 WNG
Set to 1 when the command is processed but with certain problem, e.g. written
with restriction during parameter setting.
5 Reserved Always return 0.
4 Busy Kept at 1 while command is processed.
Byte 16, bits 64 in the response show the status of the sub-command in the 32-byte mode.
Bit Title Description
6 Sub_ERR Set to 1 when error occurs during process after reception of the command.
5 Sub_WNG Set to 1 when the command is processed but with certain problem.
4 Sub_Busy Kept at 1 while command is processed.