No. SX-DSV02310 - 160 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
8-1-9 RTEX interaxis sync establishment error protection (Err90.2)
Th
is alarm will occur when communication error occurs in the full-sync mode and in sync establishment transient
condition or when the communication is interrupted.
Cause Communication error occurs in full-sync mode and in sync establishment
transient condition or the communication is interrupted.
Detecting timing RTEX communication is in RUNNING state.
Sync establishment between communication and servo is in transient condition.
Internal process upon
detecting error
After detection of alarm, RTEX communication shifts to INITIAL state.
Sync establishment condition between communication and servo is undefined.
Action Take the same measures as for Err83.0 or Err84.0.
Alarm clear attribute Cannot be cleared.
Display on COM LED Flashing in red