No. SX-DSV02310 - 74 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
6-7 Parameter Command (Command code: 6h
)
Use this to read out, to write the parameter and to write to EEPROM.
Main command: common to 16 byte and 32 byte mode
Command Response
Byte
bit7 6 5 4 3 2 1 0
Byte
bit7 6 5 4 3 2 1 0
0
C
(0)
Update_Counte
r
MAC-ID 0
R
(1)
Update_Counter
_Echo
Actual_MAC-ID
1
TMG_
CNT
6h 1
CMD_
Error
6h
2 2
3
Control_Bits
3
Status_Flags
4 L 4 L
5 ML 5 ML
6
M
H
6
M
H
7
Command_Data1
H 7
Response_Data1
H
8 Type_Code L 8 Type_Code_Echo L
9 0 H 9 ERR WNG 0 Busy H
10 L 10 L
11
Index
H 11
Index_Echo
H
12 L 12 L
13 ML 13 ML
14
M
H
14
M
H
15
Setting_Data
(Command_Data3)
H 15
Monitor_Data
H
Sub-command: specific to 32 byte mode
(Not supported): Cannot be used by a sub-command. Use only with the main command.
Title Command Response
Type_Code
/Type_Code_Echo
Type of execution, e.g. reading and writing of parameter
▪ For details, refer to Section 6-7-1.
Echo back value of Type_Code
Index
/Index_Echo
Parameter number (Type, No.)
▪ For details, refer to Section 6-7-1.
Echo back value of Index
<Reading parameter>
Data specified by Pr.7.35 (RTEX command setup 1)
▪ For details, refer to Sections 7-7-1.
<Reading parameter>
Parameter value read out *2)
[Size]: Signed 32-bit
[Unit]: Dependent on parameter
▪ For details, refer to Section 6-7-1.
<Writing parameter>
Parameter setting value *1)
[Size]: Signed 32-bit
[Unit]: Dependent on parameter
[Setting range]: Dependent on parameter
▪ For details, refer to Section 7-7-1.
<Writing parameter>
Parameter value actually written *2)
[Size]: Signed 32-bit
[Unit]: Dependent on parameter
▪ For details, refer to Section 6-7-1.
<The number read-out of the parameters in a classification>
Data specified by Pr.7.35 RTEX command 1
▪ For details, refer to Sections 7-7-1.
< Parameter initial value read-out >
Parameter initial value
▪ For details, refer to Sections 6-7-1.
<The number read-out of the parameters in a classification>
Data specified by Pr.7.35 RTEX command 1
▪ For details, refer to Sections 7-7-1.
<The number read-out of the parameters in a classification>
The number of parameters in a classification
▪ For details, refer to Sections 6-7-3.
<Parameter attribute read-out>
Data specified by Pr.7.35 RTEX command 1
▪ For details, refer to Sections 7-7-1.
<Parameter attribute read-out>
Parameter attribute
▪ For details, refer to Sections 6-7-4.
Setting_Data
(Command_Data3)
/Monitor_Data
<Writing to EEPROM>
Data specified by Pr.7.35 (RTEX command setup 1)
▪ For details, refer to Sections 7-7-1.
<Writing to EEPROM>
0 is returned.
*1) When the parameter value is 16-bit length, convert it to 32-bit.
Example: When -1000, set to FFFFFC18h
(Byte 15 = FFh, Byte 14 = FFh, Byte 13 = FCh, Byte 12 = 18h)
*2) When the parameter value is 16-bit length, it is converted to 32-bit and then returned.
During process, the value (Busy = 1) is unstable.
Compatible control mode
NOP PP CP CV CT
-
2.02.0
2.02.0
2.02.0