EasyManua.ls Logo

Panasonic MINAS-A5NL Series - 6-7 Parameter Command (Command code: \[]6 h)

Panasonic MINAS-A5NL Series
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. SX-DSV02310 - 74 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
6-7 Parameter Command (Command code: 6h
)
Use this to read out, to write the parameter and to write to EEPROM.
Main command: common to 16 byte and 32 byte mode
Command Response
Byte
bit7 6 5 4 3 2 1 0
Byte
bit7 6 5 4 3 2 1 0
0
C
(0)
Update_Counte
r
MAC-ID 0
R
(1)
Update_Counter
_Echo
Actual_MAC-ID
1
TMG_
CNT
6h 1
CMD_
Error
6h
2 2
3
Control_Bits
3
Status_Flags
4 L 4 L
5 ML 5 ML
6
M
H
6
M
H
7
Command_Data1
H 7
Response_Data1
H
8 Type_Code L 8 Type_Code_Echo L
9 0 H 9 ERR WNG 0 Busy H
10 L 10 L
11
Index
H 11
Index_Echo
H
12 L 12 L
13 ML 13 ML
14
M
H
14
M
H
15
Setting_Data
(Command_Data3)
H 15
Monitor_Data
H
Sub-command: specific to 32 byte mode
(Not supported): Cannot be used by a sub-command. Use only with the main command.
Title Command Response
Type_Code
/Type_Code_Echo
Type of execution, e.g. reading and writing of parameter
For details, refer to Section 6-7-1.
Echo back value of Type_Code
Index
/Index_Echo
Parameter number (Type, No.)
For details, refer to Section 6-7-1.
Echo back value of Index
<Reading parameter>
Data specified by Pr.7.35 (RTEX command setup 1)
For details, refer to Sections 7-7-1.
<Reading parameter>
Parameter value read out *2)
[Size]: Signed 32-bit
[Unit]: Dependent on parameter
For details, refer to Section 6-7-1.
<Writing parameter>
Parameter setting value *1)
[Size]: Signed 32-bit
[Unit]: Dependent on parameter
[Setting range]: Dependent on parameter
For details, refer to Section 7-7-1.
<Writing parameter>
Parameter value actually written *2)
[Size]: Signed 32-bit
[Unit]: Dependent on parameter
For details, refer to Section 6-7-1.
<The number read-out of the parameters in a classification>
Data specified by Pr.7.35 RTEX command 1
For details, refer to Sections 7-7-1.
< Parameter initial value read-out >
Parameter initial value
For details, refer to Sections 6-7-1.
<The number read-out of the parameters in a classification>
Data specified by Pr.7.35 RTEX command 1
For details, refer to Sections 7-7-1.
<The number read-out of the parameters in a classification>
The number of parameters in a classification
For details, refer to Sections 6-7-3.
<Parameter attribute read-out>
Data specified by Pr.7.35 RTEX command 1
For details, refer to Sections 7-7-1.
<Parameter attribute read-out>
Parameter attribute
For details, refer to Sections 6-7-4.
Setting_Data
(Command_Data3)
/Monitor_Data
<Writing to EEPROM>
Data specified by Pr.7.35 (RTEX command setup 1)
For details, refer to Sections 7-7-1.
<Writing to EEPROM>
0 is returned.
*1) When the parameter value is 16-bit length, convert it to 32-bit.
Example: When -1000, set to FFFFFC18h
(Byte 15 = FFh, Byte 14 = FFh, Byte 13 = FCh, Byte 12 = 18h)
*2) When the parameter value is 16-bit length, it is converted to 32-bit and then returned.
During process, the value (Busy = 1) is unstable.
Compatible control mode
NOP PP CP CV CT
-
2.02.0
2.02.0
2.02.0

Table of Contents

Related product manuals