Loading...
No. SX-DSV02310 - 33 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
4-2-3-5 External output signal operation instruction (EX-OUT 1/2)
The e
xternal output signal S01 and S02 from the interface connector (X4) can be controlled by assigning RTEX
operation output 1 (EX-OUT 1) and RTEX operation output 2 (EX-OUT 2) to these signals.
State of the output transistor of RTEX operation output 1 (2) is as shown below: after establishment of RTEX, before
establishment of RTEX communication after resetting and shutoff after establishment of RTEX. Note that control bit
cannot be used for controlling through RTEX communication if RTEX communication is not established after
resetting or if shutoff occurs after establishment of RTEX. Safety of the system should be taken into consideration
when setting the system.
Class No. Attribute Title Range Unit Description
7 24 C
RTEX function
expansion
setup 3
-32768
32767
bit0: Setup EX-OUT 1 output state during communication cutoff
after establishment of RTEX communication.
0: Hold
1: Initialize (output when EX-OUT 1 = 0)
bit1: Setup EX-OUT 2 output state during communication cutoff
after establishment of RTEX communication.
0: Hold
1: Initialize (output when EX-OUT 2 = 0)
State of output transistor
Signal Symbol
Pr.7.24 RTEX
function
expansion setup
3
RTEX control
bit
Communication
established
Reset
Communication
blocked
EX-OUT1 = 0 OFF
bit0 = 0
(Hold)
EX-OUT1 = 1 ON
OFF Hold
EX-OUT1 = 0 OFF
RTEX operation
output 1
EX-OUT1
bit0 = 1
(Initialize)
EX-OUT1 = 1 ON
OFF OFF
EX-OUT2 = 0 OFF
bit1 = 0
(Hold)
EX-OUT2 = 1 ON
OFF Hold
EX-OUT2 = 0 OFF
RTEX operation
output 2
EX-OUT2
bit1 = 1
(Initialize)
EX-OUT2 = 1 ON
OFF OFF

Table of Contents