No. SX-DSV02310 - 152 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
8-1-1 RTEX node address setting error protection (Err. 82.0)
Th
is alarm will occur when the value set on the node address setting rotary switch on the servo driver is outside the
setting range.
Cause The value set on the rotary switch is outside of 0 to 31.
Detecting timing Upon power up of servo driver control power supply
Upon restarting by the reset command
Internal process upon
detecting error
RTEX communication is not established (aborted due to incomplete
initialization)
RTEX communication state is kept INITIAL (transition).
Action Check the value set on the node address setting rotary switch.
When necessary, correct the setting value (031), and turn on the servo driver
control power.
Replace the servo driver as necessary.
Alarm clear attribute Cannot be cleared.
Display on COM LED Lighting in red
7-seg LED (2-digit)
Node address setting rotary switch
Setting range: 0–31
LINK LED
COM LED