No. SX-DSV02310 - 75 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
6-7-1 Type code list of parameter command
Type_Code *1)
Compatible
as before
New
Title Description
000h - Undefined Do not use this Type_Code with MINAS-A5N.
Command error (0031h) will be returned
001h - Undefined Do not use this Type_Code with MINAS-A5N.
Command error (0031h) will be returned
- 010h Parameter
reading
Use this to read out the parameter value from the servo driver.
Set the parameter number (class, No.) to Index of command.
Byte Title Description
10 Index-L Parameter No.
11 Index-H Parameter class
Set the data specified in Pr.7.35 (RTEX command setup 1) to
Setting_Data of command.
Return the readout value as Monitor_Data in the response.
• If Index is unsupported parameter number (No. or class is outside of
range) , command error 0032h will be returned.
• When Pr.7.35 RTEX command setup 1 is 0, and Command_Data3 is not
0, Command error (0032h) will be returned.
- 011h Parameter
writing
Use this to write the parameter value to the servo driver.
Set the parameter number (class, No.) to Index of command.
Byte Title Description
10 Index-L Parameter No.
11 Index-H Parameter class
• Set the writing value to Setting_Data.
Actual written value will be returned to the Monitor_Data of the response.
When the parameter was set by the limited value that is different from the
command value, WNG bit will be 1.
If Index is unsupported parameter number (No. or class is outside of
range) or if Setting_Data is other than 0, command error 0032h will be
returned.
When No. and class are within the range but not supported, command
error 0032h will be returned with Setting_Data other than 0.
When the bit 0 of Pr.7.23 (RTEX function expansion setup 2) is set at 1,
the command cannot be executed. And command error 0201h will be
returned.
Command error 0041h will be returned if you try to a parameter of read
only attribute.
-
020h
Parameter initial
value read-out
The initial value of a parameter is read-out.
Set the parameter number (class, No.) to Index of command.
Byte Title Description
10 Index-L Parameter No.
11 Index-H Parameter class
Set Data specified by Pr.7.35 RTEX command setup 1 as
Command_Data3.
Read-out value will be returned to the Monitor_Data of the
response.
When Index is outside the parameter number (No. or class), Command
error(0032h) will be returned.
When Pr.7.35 RTEX command setup 1 is 0, and Command_Data3 is not
0,Command error (0032h) will be returned.