EasyManua.ls Logo

Panasonic MINAS-A5NL Series - Page 84

Panasonic MINAS-A5NL Series
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. SX-DSV02310 - 76 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
*1) Command error (0031h) will be returned at setting up the wrong type code.
Type_Code *1)
Compatible
as before
New
Title Description
-
030h
The number
read-out
of the
parameters in a
classification
The number of the parameters in a classification is read.
Set the parameter class number to Index-H of command.
Fix 0 to Index-L of command.
Byte Title Description
10 Index-L Fix 0
11 Index-H Parameter class
Set Data specified by Pr.7.35 RTEX command setup 1 as
Command_Data3.
When Index-L is not 0, Command error (0032h) will be returned.
When the classification number in which a parameter does not exist is
specified, 0 will be returned.
When Index-H is outside the parameter classification number,
Command error(0032h) will be returned.
When Pr.7.35 RTEX command setup 1 is 0, and Command_Data3 is not
0,Command error (0032h) will be returned.
-
040h
Parameter
attribute
read-out
The attribute of a parameter is read-out.
Set the parameter number (class, No.) to Index of command.
Byte Title Description
10 Index-L Parameter No.
11 Index-H Parameter class
Set Data specified by Pr.7.35 RTEX command setup 1 as
Command_Data3.
When Index is outside the parameter number (No. or class), Command
error(0032h) will be returned.
When Pr.7.35 RTEX command setup 1 is 0, and Command_Data3 is not
0,Command error (0032h) will be returned.
101h 081h EEPROM
writing
Save the parameter value to EEPROM in the servo driver. (An error
might occur during processing. In this case, ERR bit will be 1 instead of
command error, and retry to transmit command.)
• Set 0 to Index of command.
• Set Data specified by Pr.7.35 RTEX command setup 1 as
Command_Data3.
• When Index is not 0, Command error (0032h) will be returned.
• When Pr.7.35 RTEX command setup 1 is 0, and Command_Data3 is not
0, Command error (0032h) will be returned.
When Err. 11.0 (Control power supply under-voltage protection) occurs,
command error (0061h) will be returned because of EEPROM accessing
failure.
When the bit 0 of Pr.7.23 (RTEX function expansion setup 2) is set at 1,
the command cannot be executed. And command error 0201h will be
returned.
*1) Command error (0031h) will be returned at setting up the wrong type code.
2.02.0
2.02.0
2.02.0

Table of Contents

Related product manuals