Loading...
No. SX-DSV02310 - 32 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
4-2-3-4 Speed limit switching command (SL_SW)
Wh
en the setting value of Pr.3.17 (Selection of speed limit) is 1, the speed limit value during thrust controlling can be
selected from SL_SW.
Class No. Attribute Title Range Unit Description
3 17 B
Selection of
speed limit
0–1 –
Set the speed limit value selection method for thrust
controlling.
Setup value SL_SW = 0 SL_SW = 1
0 Pr.3.21
1 Pr.3.21 Pr.3.22
3 21 B
Speed limit
value 1
0
20000
mm/s
Set the speed limit value for thrust controlling.
During thrust controlling, the speed set by the speed limit
value will not be exceeded.
The internal value is limited by the setting of Pr.5.13
(Overspeed level setting), Pr 6.15 (2nd overspeed level
setting) or Pr9.10 (Maximum overspeed level setting),
whichever lowest.
3 22 B
Speed limit
value 2
0
20000
mm/s
When Pr.3.17 (Selection of speed limit) = 1, set the speed
limit value as specified by SL_SW = 1.
The internal value is limited by the setting of Pr. 5.13
(Overspeed level setting), Pr. 6.15 (2nd overspeed level
setting) or Pr. 9.10 (Maximum overspeed level setting),
whichever lowest.

Table of Contents