No. SX-DSV02310 - 69 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
6-6 Alarm command (Command code: 5h
)
Use this to read out alarm code or clear the present alarm.
Main command: common to 16 byte and 32 byte mode
Command Response
Byte
bit7 6 5 4 3 2 1 0
Byte
bit7 6 5 4 3 2 1 0
0
C
(0)
Update_Counte
r
MAC-ID 0
R
(1)
Update_Counter
_Echo
Actual_MAC-ID
1
TMG_
CNT
5h 1
CMD_
Error
5h
2 2
3
Control_Bits
3
Status_Flags
4 L 4 L
5 ML 5 ML
6
M
H
6 MH
7
Command_Data1
H 7
Response_Data1
H
8 Type_Code L 8 Type_Code_Echo L
9 0 H 9 ERR WNG 0 Busy H
10 L 10 L
11
Index
H 11
Index_Echo
H
12 L 12 Main
13 ML 13
Alarm_Code
Sub
14
M
H
14 L
15
Command_Data3
H 15
Warning_Code
H
Sub-command: specific to 32 byte mode
(Not supported): Cannot be used by a sub-command. Use only with the main command.
Title Command Response
Type_Code
/Type_Code_Echo
Type of execution, e.g. alarm readout and clear
▪ For details, refer to Section 6-6-1.
Echo back value of Type_Code
<Except for alarm attribute readout>
Echo back value of Index
Index
/Index_Echo
Set up history number etc.
▪ For details, refer to Section 6-6-1.
<To read out alarm attribute>
Index: 0 Alarm code being issued
Index: not 0 Echo back value of Index
Command_Data3 Data specified by Pr.7.35 (RTEX command setup 1)
▪ For details, refer to Sections 7-7-1.
-
<Except for alarm attribute readout>
Alarm code
▪ For details, see 6-6-1 and 6-6-2.
Alarm_Code
<To read out alarm attribute>
Alarm attribute
▪ For details, see 6-6-3.
<Except for alarm attribute readout>
Warning code
▪ For details, see 6-6-1.
Warning_Code
<To read out alarm attribute>
Alarm attribute
▪ For details, see 6-6-3.
Compatible control mode
NOP PP CP CV CT
-