EasyManua.ls Logo

Panasonic MINAS-A5NL Series - 6-6 Alarm command (Command code: \[]5 h)

Panasonic MINAS-A5NL Series
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. SX-DSV02310 - 69 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
6-6 Alarm command (Command code: 5h
)
Use this to read out alarm code or clear the present alarm.
Main command: common to 16 byte and 32 byte mode
Command Response
Byte
bit7 6 5 4 3 2 1 0
Byte
bit7 6 5 4 3 2 1 0
0
C
(0)
Update_Counte
r
MAC-ID 0
R
(1)
Update_Counter
_Echo
Actual_MAC-ID
1
TMG_
CNT
5h 1
CMD_
Error
5h
2 2
3
Control_Bits
3
Status_Flags
4 L 4 L
5 ML 5 ML
6
M
H
6 MH
7
Command_Data1
H 7
Response_Data1
H
8 Type_Code L 8 Type_Code_Echo L
9 0 H 9 ERR WNG 0 Busy H
10 L 10 L
11
Index
H 11
Index_Echo
H
12 L 12 Main
13 ML 13
Alarm_Code
Sub
14
M
H
14 L
15
Command_Data3
H 15
Warning_Code
H
Sub-command: specific to 32 byte mode
(Not supported): Cannot be used by a sub-command. Use only with the main command.
Title Command Response
Type_Code
/Type_Code_Echo
Type of execution, e.g. alarm readout and clear
For details, refer to Section 6-6-1.
Echo back value of Type_Code
<Except for alarm attribute readout>
Echo back value of Index
Index
/Index_Echo
Set up history number etc.
For details, refer to Section 6-6-1.
<To read out alarm attribute>
Index: 0 Alarm code being issued
Index: not 0 Echo back value of Index
Command_Data3 Data specified by Pr.7.35 (RTEX command setup 1)
For details, refer to Sections 7-7-1.
<Except for alarm attribute readout>
Alarm code
For details, see 6-6-1 and 6-6-2.
Alarm_Code
<To read out alarm attribute>
Alarm attribute
For details, see 6-6-3.
<Except for alarm attribute readout>
Warning code
For details, see 6-6-1.
Warning_Code
<To read out alarm attribute>
Alarm attribute
For details, see 6-6-3.
Compatible control mode
NOP PP CP CV CT
-

Table of Contents