No. SX-DSV02310 - 162 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
8-1-11 RTEX hardware error protection 1/2/3 (Err. 98.1/Err. 98.2/Err. 98.3)
T
his alarm occurs when an error occurs in RTEX communication circuit.
Cause An error occurs on RTEX communication circuit.
Detecting timing On power up of servo driver control power.
Upon restarting by the reset command.
Internal process upon
detecting error
RTEX communication cannot be established due to incomplete initialization.
RTEX communication status is still in INITIAL condition (transition).
Action Replace the servo driver if the cause is not removed after turning on control
power.
Alarm clear attribute Cannot be cleared.
Display on COM LED Lighting in red