No. SX-DSV02310 - 91 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
Type_Code
Conventional New
Title Index Unit Description Refer to
- 67h Fan life expectancy - - 0.1%
Percent of fan life expectancy.
Because the power on time is recorded in unit of 30
minutes, a turn-on period shorter than 30 minutes is
not recorded.
0 when no fan is installed.
-
- 68h
Capacitor life
expectancy
- - 0.1%
Percent life expectancy of main power source
capacitor
Because the power on time is recorded in unit of 30
minutes, a turn-on period shorter than 30 minutes is
not recorded.
- 69h Voltage across PN - - V Main power source PN voltage -
401h 71h RTEX cumulative
communication errors
- 0 Cycle Total number of RTEX communication errors
Saturation occurs at max. value FFFFh.
The count will be cleared upon restarting of servo
driver or resetting of control power source.
-
411h 81h Maker use - – – -
412h 82h Maker use - – – -
- 83h Feedback scale
cumulative
communication errors
- 0 Cycle Total (cumulative) number of communication errors
between feedback scale
Saturation occurs at max. value FFFFh.
The count will be cleared upon restarting of servo
driver or resetting of control power source.
-
- 84h Feedback scale
cumulative
communication data
errors
- 0 Cycle Total (cumulative) number of communication errors
between feedback scale
Saturation occurs at max. value FFFFh.
The count will be cleared upon restarting of servo
driver or resetting of control power source.
-
- 91h Estimation accuracy of
magnetic pole position
- 0 Degree Estimation accuracy when execution of estimating
magnetic pole position
(Electric angle: 0 – 180 [degree])
Example) When the value is 10, it means estimation
accuracy of magnetic pole position is
within 10 [degree] of electric angle.
The smaller in this value, the better in accuracy.
This accuracy is accuracy estimated from magnetic
pole position estimation method and does not
guarantee actual accuracy. Use it as a reference.
When estimation of magnetic pole position is not
completed, 0 is returned.
When estimation of magnetic pole position is in
execution, 180 is returned.
When estimation of magnetic pole position is error,
180 is returned.
When Pr9.20 (Selection of magnetic pole detection
method) 2 (other than magnetic pole estimation
method), 0 is returned.
-
- 92h Execution time of
estimation of magnetic
pole position
- 0 ms Execution time when estimating magnetic pole
position
Value is renewed after completion of magnetic pole
position estimation.
When Pr9.20 (Selection of magnetic pole detection
method) 2 (other than magnetic pole estimation
method), 0 is indicated.
-
- 93h Maximum travel
distance to plus
direction when
estimating magnetic
pole position
- 0 pulse
(feedback
scale order)
Making starting position for estimation of magnetic
pole position as a base, returns maximum travel
distance [pulse] to plus direction.
Value is renewed after completion of magnetic pole
position estimation.
When Pr9.20 (Selection of magnetic pole detection
method) 2 (other than magnetic pole estimation
method), 0 is indicated.
-
- 94h Maximum travel
distance to minus
direction when
estimating magnetic
pole position
- 0 Pulse
(feedback
scale order)
Making starting position for estimation of magnetic
pole position as a base, returns maximum travel
distance [pulse] to minus direction.
Value is renewed after completion of magnetic pole
position estimation.
When Pr9.20 (Selection of magnetic pole detection
method) 2 (other than magnetic pole estimation
method), 0 is indicated.
-