No. SX-DSV02310 - 91 -
R2.0 Motor Business Division, Appliances Company, Panasonic Corporation
Type_Code
Conventional New
Title Index Unit Description Refer to
- 67h Fan life expectancy - - 0.1%
Percent of fan life expectancy.
▪ Because the power on time is recorded in unit of 30
minutes, a turn-on period shorter than 30 minutes is
not recorded.
▪ 0 when no fan is installed.
-
- 68h
Capacitor life
expectancy
- - 0.1%
Percent life expectancy of main power source
capacitor
▪ Because the power on time is recorded in unit of 30
minutes, a turn-on period shorter than 30 minutes is
not recorded.
- 69h Voltage across PN - - V Main power source PN voltage -
401h 71h RTEX cumulative
communication errors
- 0 Cycle Total number of RTEX communication errors
▪ Saturation occurs at max. value FFFFh.
The count will be cleared upon restarting of servo
driver or resetting of control power source.
-
411h 81h Maker use - – – – -
412h 82h Maker use - – – – -
- 83h Feedback scale
cumulative
communication errors
- 0 Cycle Total (cumulative) number of communication errors
between feedback scale
▪ Saturation occurs at max. value FFFFh.
The count will be cleared upon restarting of servo
driver or resetting of control power source.
-
- 84h Feedback scale
cumulative
communication data
errors
- 0 Cycle Total (cumulative) number of communication errors
between feedback scale
▪ Saturation occurs at max. value FFFFh.
The count will be cleared upon restarting of servo
driver or resetting of control power source.
-
- 91h Estimation accuracy of
magnetic pole position
- 0 Degree Estimation accuracy when execution of estimating
magnetic pole position
(Electric angle: 0 – 180 [degree])
Example) When the value is 10, it means estimation
accuracy of magnetic pole position is
within 10 [degree] of electric angle.
▪ The smaller in this value, the better in accuracy.
▪ This accuracy is accuracy estimated from magnetic
pole position estimation method and does not
guarantee actual accuracy. Use it as a reference.
▪ When estimation of magnetic pole position is not
completed, 0 is returned.
▪ When estimation of magnetic pole position is in
execution, 180 is returned.
▪ When estimation of magnetic pole position is error,
180 is returned.
▪ When Pr9.20 (Selection of magnetic pole detection
method) ≠2 (other than magnetic pole estimation
method), 0 is returned.
-
- 92h Execution time of
estimation of magnetic
pole position
- 0 ms Execution time when estimating magnetic pole
position
▪ Value is renewed after completion of magnetic pole
position estimation.
▪ When Pr9.20 (Selection of magnetic pole detection
method) ≠2 (other than magnetic pole estimation
method), 0 is indicated.
-
- 93h Maximum travel
distance to plus
direction when
estimating magnetic
pole position
- 0 pulse
(feedback
scale order)
Making starting position for estimation of magnetic
pole position as a base, returns maximum travel
distance [pulse] to plus direction.
▪ Value is renewed after completion of magnetic pole
position estimation.
▪ When Pr9.20 (Selection of magnetic pole detection
method) ≠2 (other than magnetic pole estimation
method), 0 is indicated.
-
- 94h Maximum travel
distance to minus
direction when
estimating magnetic
pole position
- 0 Pulse
(feedback
scale order)
Making starting position for estimation of magnetic
pole position as a base, returns maximum travel
distance [pulse] to minus direction.
▪ Value is renewed after completion of magnetic pole
position estimation.
▪ When Pr9.20 (Selection of magnetic pole detection
method) ≠2 (other than magnetic pole estimation
method), 0 is indicated.
-