102 I11 T11 192-120101 N6 - March 2004
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFAF
Error:
SinCos invalid access code
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFB0
Error:
SinCos size of the stated data field is not variable
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFB1
Error:
SinCos stated word address outside data field
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFB2
Error:
SinCos access to non-existent data field
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFBC
Error:
SinCos absolute value control of the analog signals
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFBD
Error:
SinCos transmitter current approaching limit
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFBE
Error:
SinCos feedback temperature approaching limit
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFBF
Error:
SinCos speed exceeds normal, no position generation permitted.
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFC0
Error:
SinCos Position Singleturn unreliable
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFC1
Error:
SinCos position error Multiturn
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Change feedback
Note:
Feedback reports error
Error code (hex):
0xFFC2
0xFFAF
0xFFB0
0xFFB1
0xFFB2
0xFFBC
0xFFBD
0xFFBE
0xFFBF
0xFFC0
0xFFC1
0xFFC2

Table of Contents

Other manuals for Parker Compax3 S150 V4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 S150 V4 and is the answer not in the manual?

Parker Compax3 S150 V4 Specifications

General IconGeneral
Output Current150 A
Control TypeDigital
SeriesCompax3
ModelS150 V4
Enclosure RatingIP20
Communication InterfacesCANopen, RS-232, RS-485
Feedback OptionsResolver
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Relative Humidity5 to 95% non-condensing
Operating Temperature0 to +45 °C (32 to 113 °F)