104 I11 T11 192-120101 N6 - March 2004
Error code (hex):
0xFFE1
Error:
CamOut not possible during coupling process
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
PLCopen function module CamOut cannot be called during coupling
process.
Note:
Error in the IEC61131-3 program sequence. PLCopen function module
CamOut was called even though the axis was not yet coupled.
Error code (hex):
0xFFE2
Error:
Invalid parameter transfer while calling a function module.
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Call PLCopen function module with matching parameters.
Note:
Error in the IEC61131-3 program sequence. Function module was called
with incorrect parameters.
Error code (hex):
0xFFE3
Error:
Coupling // decoupling only possible with C3_CamIN or C3_CamOut Mode
0
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Coupling with a linear actuator only possible with Mode 0.
Note:
Error in the IEC61131-3 program sequence. An attempt was made with a
linear actuator to couple with another mode than 0.
0xFFE1
0xFFE2
0xFFE3

Table of Contents

Other manuals for Parker Compax3 S150 V4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 S150 V4 and is the answer not in the manual?

Parker Compax3 S150 V4 Specifications

General IconGeneral
Output Current150 A
Control TypeDigital
SeriesCompax3
ModelS150 V4
Enclosure RatingIP20
Communication InterfacesCANopen, RS-232, RS-485
Feedback OptionsResolver
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Relative Humidity5 to 95% non-condensing
Operating Temperature0 to +45 °C (32 to 113 °F)

Related product manuals