I11 T11 192-120101 N6 - March 2004 143
Special encoder systems for direct
drives
Option F12
Analog hall sensors
! Sine - cosine signal (max. 5Vss
4
; typical
1Vss) 90° offset
! U-V Signal (max. 5Vss
5
; typical 1Vss)
120° offset.
Encoder
(linear or rotatory)
! Sine-cosine (max. 5Vss
6
; typical 1Vss)
(max. 400kHz) or
! TTL (RS422) (max. 5MHz)
with the following modes of commutation:
! automatic commutation (see on page
108) or
! Digital hall sensors
Distance coded
feedback systems
! Distance coding with 1VSS - Interface
! Distance coding with RS422 - Interface
(Encoder)
Interfaces
Interface selection by external plug contact assignment
RS232
! 115200 baud
! Word length: 8 bits, 1 start bit, 1 stop bit
! Hardware handshake XON, XOFF
RS485 (2 or 4-wire)
! 9600, 19200, 38400, 57600 or 115200
baud
! Word length 7/8 bit, 1 start bit, 1 stop bit
! Parity (can be switched off) even/odd
! 2 or 4-wire
Motor holding brake output
Controller type Compax3
Voltage range
21 – 27VDC
Maximum output current (short circuit
proof)
1.6 A
Brake operation Compax3 Sxxx V2
Controller type S025 V2 S063 V2
Capacitance / storable energy
560µF / 15Ws 1120µF /30Ws
Minimum ballast - resistance
100 56
Recommended nominal power rating
20 ... 60W 60 ... 180W
Pulse power rating for 1s
1kW 2.5kW
Compax3 Sxxx V4 brake operation
Controller type S038 V4 S075 V4 S150 V4 S300 V4
4
Max. differential input between SIN- (X13/7) and SIN+ (X13/8).
5
Max. differential input between SIN- (X13/7) and SIN+ (X13/8).
6
Max. differential input between SIN- (X13/7) and SIN+ (X13/8).