EasyManuals Logo

Parker Compax3 S150 V4 User Manual

Parker Compax3 S150 V4
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
Parker EME
Error
I11 T11 192-120101 N6 - March 2004 93
Error code (hex):
0x3222
Error:
Voltage in DC bus too low (< 70V)
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Measurement via PAP
Error code (hex):
0x4210
Error:
Temperature of power output stage / device
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Measurement via PAP; source from power stage
Error code (hex):
0x4310
Error:
Motor temperature
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Source is motor temperature signal
Error code (hex):
0x5111
Error:
Auxiliary voltage 15V defective
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Measurement via PAP
Error code (hex):
0x5112
Error:
Overvoltage 24V
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Measurement via PAP
Error code (hex):
0x5116
Error:
Undervoltage 24V
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Measurement via PAP
Error code (hex):
0x5117
Error:
Undervoltage options
Error reaction:
None
Measure:
Note:
Used for M expansion with I/O if the external power supply is missing
Error code (hex):
0x5380
Error:
Short circuit at digital output
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Applies to the 4 on-board outputs
Error code (hex):
0x5420
Error:
Ballast resistor overload, pulse current
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Setting via tool input
Error code (hex):
0x5421
Error:
Braking Resistor overloaded (Continuous Current)
Error reaction:
Reaction 2: downramp / apply brake / deenergize.
Measure:
Note:
Setting via tool input
Error code (hex):
0x5480
Error:
Short Circuit - Motor Brake
Error reaction:
None
Measure:
0x3222
0x4210
0x4310
0x5111
0x5112
0x5116
0x5117
0x5380
0x5420
0x5421
0x5480

Table of Contents

Other manuals for Parker Compax3 S150 V4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 S150 V4 and is the answer not in the manual?

Parker Compax3 S150 V4 Specifications

General IconGeneral
Output Current150 A
Control TypeDigital
SeriesCompax3
ModelS150 V4
Enclosure RatingIP20
Communication InterfacesCANopen, RS-232, RS-485
Feedback OptionsResolver
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Relative Humidity5 to 95% non-condensing
Operating Temperature0 to +45 °C (32 to 113 °F)