Problem: Indoor and Outdoor Control Panels work, but iS10 fails to operate.
Symptom Possible Cause Solution
iS10 Spa Side fails to oper-
ate equipment .
Spa Side Control is
Disabled from the
main control panel.
Using the indoor panel or a serviceman’s panel.
Press ‘MENU’ and ensure the selection reads
“SPA SIDE REMOTE ENABLED”. If it reads “SPA
SIDE REMOTE DISABLED” press the button
beside the option to toggle the selection.
Defective Wiring
Verify iS10 setup. Press ‘MENU/SETUP/AD-
VANCED/SPA, RF, & PHONE REMOTES’Select
‘CONFIGURE iS10’s . Ensure the iS10 in question
has the expected circuit assignments, and is not
assigned to unused circuits.
Incorrect configu-
ration or circuit to
switch assignment.
Verify iS10 setup. Press ‘MENU/SETUP/AD-
VANCED/SPA, RF, & PHONE REMOTES’Select
‘CONFIGURE iS10’s’ Ensure the iS10 in question
has the expected circuit assignments, and is not
assigned to unused circuits.
IS10 is not correctly
enabled
See page 80 to manually enable the iS10.
Defective iS10
Replace defective iS10. Contact Technnical Sup-
port.

Table of Contents

Other manuals for Pentair INTELLITOUCH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair INTELLITOUCH and is the answer not in the manual?

Pentair INTELLITOUCH Specifications

General IconGeneral
Remote AccessYes, via mobile app
Lighting ControlYes
AutomationYes
ExpandabilityYes
InterfaceTouchscreen, mobile app
Enclosure RatingNEMA 3R
User InterfaceTouchscreen
CompatibilityPentair equipment
ConnectivityEthernet, Wireless
Mobile ControlYes
Remote ControlYes
Communication ProtocolPentair proprietary
Control TypeAutomated

Related product manuals