14
Dimming Lights
In order to dim lights, the Dimmer Module (P/N 520406) must be installed by a qualied electrician
in the IntelliTouch Load Center or Power Center. Only incandescent tungsten lament lights can be
dimmed (not Halogen lights). Lights that have dimming functionality can be dimmed from the Lights
screen. SAm or SAL ber optic lights, MagicStream Laminars, Halogen and IntelliBrite lights cannot
be dimmed. For more information, refer to “Setting up Lighting Options,” page 42. The circuit must be
assigned to the “Dimmer” circuit function (see page 41) in order to operate correctly.
To dim lights, go to the assigned circuit name:
1. Press the button next to the circuit name. A light should
come on and be switched on at the specied dimming
level.
2. To change the dimming level, hold the circuit button
down until the DimmerLevelSettings screen displays as
shown.
3. Press the button next to Decrease to decrease the dimming
level, and the button next to Increase to increase the
dimming level. The percent value displays the current
dimming level setting.
4. Press Savewhen done. The light will adjust to the set dimming level.
Note:Macros can turn on light dimming circuits, but lights cannot be dimmed through the macro.
The dimming level must be changed for each light dimming circuit.
Setting ON/OFF Times for Equipment (PROGRAM)
You can create schedules to automatically run equipment like pool ltration or lights. Any circuit can be set to
switch on and off on every day of the week. When a relay is switched on manually, it remains on until you either
switch it off manually, or the next time the relay is scheduled to be switched off. For example, if the lter pump
or any circuit is scheduled to run from 9AM to 4 PM and the programmed schedule is turned OFF at 1:00 PM and
then turned on at 1:10 PM, the circuit will turn OFF at its programmed OFF time of 4:00 PM. But if the circuit
is turned on after 4:00 PM, the factory set Egg Timer of 12 hours is now engaged. So if the circuit was turned
on at 6:00 PM that circuit will turn off at 6:00 AM (12 hours later). If the circuit was turned ON at 5:00 PM and
because a programmed OFF time had been set to turn off at 4:00 PM, the circuit would operate for 11 hours. A spa
or pool program can be overridden using the Spa or Pool button to switch the circuit on.
From the “Program” screen, you can schedule IntelliTouch to automatically run equipment like pool ltration or
lights. Any circuit (auxiliary, feature, or macro) can be scheduled to switch on and off at a specic time and on a
any day(s) of the week. Up to 99 total programs may be created for all circuits combined.
Scheduleaprogram: The “Program” screen displays a program counter in the upper right (1/0) side of the
screen. This counter indicates the current number of scheduled programs. After setting the start and stop time and
the day(s) to run the rst scheduled program, press Save to view the rst program (1/1) and increment the counter
to next program. To access the next program screen, press the button next to the counter label (2/1). Set the start
and stop time and the day(s) to run the second scheduled program (2/1). Repeat this process to enter another
program. For example, 2/3 indicates that you are viewing program2 of3 total programs saved for that circuit.
4/3 indicates that you are creating program 4 but only 3 are currently saved. After pressing the Save button, the
counter updates to 4/4. Press the button to the right of the label counter to step through each program rst then
display the unsaved program screen. The following describes how to program equipment to run the pool ltration
system. This process is the same for any installed equipment listed on the screen.
MENU SETUP ADVANCED CIRCUIT FUNCTION
(NAME)
Getting There
DIMMER LEVEL SETTINGS
60%
DIMMER CIRCUIT AUX1
EXIT

Table of Contents

Other manuals for Pentair INTELLITOUCH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair INTELLITOUCH and is the answer not in the manual?

Pentair INTELLITOUCH Specifications

General IconGeneral
Remote AccessYes, via mobile app
Lighting ControlYes
AutomationYes
ExpandabilityYes
InterfaceTouchscreen, mobile app
Enclosure RatingNEMA 3R
User InterfaceTouchscreen
CompatibilityPentair equipment
ConnectivityEthernet, Wireless
Mobile ControlYes
Remote ControlYes
Communication ProtocolPentair proprietary
Control TypeAutomated

Related product manuals