IntelliTouch
®
Control System User’s Guide
63
IntelliFlo VF 3050 pump setup (Continued)
Assign custom flows
From the Assign Custom Flows screen you can assign different (normally higher) ows to circuits/
features. For example you can set your SPA to run at 80 GPM. This way when you switch to spa mode,
the pump goes from the calculated tter rate of about 28 GPM to 80 GPM while you use the spa. You
have a waterfall, and require 60 GPM when it’s switched on.
T
o assign a specic ow to a circuit/feature:
1. From the main pump screen, press the left side button next to the select IntelliFlo pump.
2. On the next screen, press the left side button next to ASSIGNCUSTOMFLOWS.
3. First assign a circuit name. Press the left side button for the selected circuit. Use the PREV and
NEXT button to set the circuit. Then press the right side button to set the ow rate in GPM. The
selected circuit/feature must also be assigned a circuit function/feature. For details about assigning
a circuit function and feature circuit, see page 39 and 79.
4. When nished, press the lower SAVE button to save the setting. The previous pump parameters
screen is displayed. To modify another parameter select a feature from the parameter list. To exit,
press the EXIT button to return to the Equipment screen.
MENU/SETP/EQUIP/INTELLIFLO/ASSIGN
BACK EXIT
NONE 0 GPM
NONE 0 GPM
NONE 0 GPM
NEXT PAGE
AUX 7 130 GPM
SAVE PREV
Press this button
to set the flow
rate (GPM)
Prev and Next buttons
(use to adjust pump
speed)
Save button
Press this
button go to four
additional circuits/
GPM settings