THE NEW PIPER AIRCRAFT, INC.
PA-32-301FT / 301XTC
MAINTENANCE MANUAL
PAGE 13
Jun 1/03
3J3
35-10-00
(d) Hold the fitting body steady with a backup wrench and tighten as follows:
(a) On tubing with a diameter bigger than 3/16 inch, tighten 1 1/4 turns (to the nine
o'clock position).
(b) On tubing of 1/16, 1/8, and 3/16 inch diameter, tighten only 3/4 turn.
(e) If nut and tube must be disconnected from the fitting, reconnect by seating the tube on the
shoulder of the fitting and tightening the nut finger tight. Follow up by tightening the nut
with a wrench, one quarter turn (if absolutely necessary the original 1 1/4 or 3/4 tight
position) and then snug with wrench.
(2) Preswaged swageloc fittings are fabricated and installed as follows:
(a) Assemble the nut and ferrules finger tight on the preswaging tool and insert the tube until
it firmly bottoms on the shoulder in the tool. The preswaging tool can be attained from
Crawford Fitting Company, refer to List of Consumable Materials in Chapter 91.
(b) Tighten the nut on the fitting just enough that the tube within the fitting will not turn by
hand.
(c) With a wrench, tighten the nut as follows:
1
On tubing with diameters over 3/16 inch, tighten 1 1/4 turns.
2
On tubing with 1/16, 1/8, or 3/16 inch diameter, tighten 3/4 of a turn.
(d) Unscrew the nut to release the ferrule-tube assembly from the tool.
(e) The assembly is installed on the fitting as follows:
1
Slide tube in fitting until it bottoms, turn nut to finger tight position and tighten one
quarter turn with wrench.
2
Snug slightly with wrench.
F. Application of Teflon Tape Thread Sealant
All male pipe (tapered) threads of the oxygen system should be sealed with 3M No. 48 teflon tape.
Teflon tape should not be used on straight threads. Do not use any other lubricants in place of the
teflon or on any other threads.
(1) Wrap tape on the threads, starting with those farthest from the opening, in the direction of the
thread spiral. Circle the threads, making sure that each side of the tape has a slight overlap.
(2) Wrap the tape such that it does not extend beyond the last thread on the fitting at the opening.
The tape should then be pulled till it separates. Do not cut tape, it will not stick properly.