THE NEW PIPER AIRCRAFT, INC.
PA-32-301FT / 301XTC
MAINTENANCE MANUAL
PAGE 3
Feb 19/04
1E3
5-30-00
Each Six (6) Months
 If annual usage is significantly less than 100 Hours, lubricate propeller each six (6) months. See Hartzell
Standard Practices Manual No. 202A.
Each Twelve (12) Months
 Lubricate propeller every 100 Hours or annually, whichever comes first. If annual usage is significantly
less than 100 Hours, lubricate propeller each six (6) months. See Hartzell Standard Practices Manual
No. 202A.
For airplanes equipped with the Avidyne Entegra Electronic Flight Display System: each twelve months,
perform a full capacity test of the Standby Attitude Indicator battery. See Standby Attitude Indicator, 34-20-00.
Each Two (2) Years
 Test and inspect the static pressure system and altimeters. Ensure compliance with the requirements of
FAR 43, Appendix E. (See FAR 91.411.)
 Test and inspect the transponder. Ensure compliance with the requirements of FAR 43, Appendix F.
(See FAR 91.413.)
Each Three (3) Years
W
ARNING: DO NOT USE GREASE OR ANY TYPE OF GREASE FITTING ON ANY OXYGEN
SYSTEM. WHEN WORKING WITH AN OXYGEN SYSTEM MAKE SURE HANDS,
CLOTHING, TOOLS, AND IMMEDIATE AREA ARE FREE OF GREASE.
 For S/N’s 3255001 & up only: If installed, remove and hydrostatically test oxygen cylinder every three (3)
years (i.e. - light weight composite cylinders - DOT E8162). No lightweight composite oxygen cylinder
may exceed fifteen (15) years total time-in-service.
Each Five (5) Years
W
ARNING
: DO NOT USE GREASE OR ANY TYPE OF GREASE FITTING ON ANY OXYGEN
SYSTEM. WHEN WORKING WITH AN OXYGEN SYSTEM MAKE SURE HANDS,
CLOTHING, TOOLS, AND IMMEDIATE AREA ARE FREE OF GREASE.
 For S/N’s 3255001 & up only: If installed, for each oxygen system outlet, replace rubber components or
entire outlet assembly each five (5) years time-in-service.
 For S/N’s 3255001 & up only: If installed, replace oxygen system external recharge valve each five (5)
years time-in-service.
 Replace engine-driven or electric fuel pumps at engine overhaul or five (5) years, whichever comes first.
 Overhaul or replace Hartzell propellers each five (5) or six (6) years or each 2000 or 2400 hours. (Refer
to latest revision of Hartzell Service Letter No. 61 to determine specific requirements for individual
airplanes.)