Remote control commands
R&S
®
LCX Series
205User Manual 1179.2260.02 ─ 02
Example: Using the MEASure commands
The example represents the remote control commands to set the measurement mode,
to query the voltage or current values, and the measurement accuracy.
*************************************************
// Query current and voltage values of the next working point
MEASure:VOLTage?
// Response: 2 // 2 V
MEASure:CURRent?
// Response: 0.1 // 100 mA
// Select the measurement mode and set a trigger delay
MEASure:MODE TRIGgered
MEASure:TRIGger:DELay 2
// Start the measurement manually
*TRG
*************************************************
// Query the measurement accuracy
MEASure:ACCuracy?
// Response: 2.123, 1.123 // percent, degree
Example: Using the INITiate command
The example represents the remote control commands for triggering a measurement.
*************************************************
// Start the measurement manually
*TRG
// Start a new measurement immediately
INITiate[:IMMediate]