2-771-001 PTr:Std:1 *ENG [0 to 995 / 100 / 5%/step]
2-771-002 PTr:Std:2 *ENG
2-771-003 PTr: Low: 1st *ENG
2-771-004 PTr: Low: 2nd *ENG
2-771-005 SepaDC:Std:1st *ENG
2-771-006 SepaDC:Std:2nd *ENG
2-771-007 SepaDC:Low:1st *ENG
2-771-008 SepaDC:Low:2nd *ENG
2772 [SP 1:SW Tmng:LE] DFU
Adjusts the bias/ voltage switch timing of the paper transfer roller/ discharge plate at
the paper leading edge between the erase margin area and the image area.
Standard: 260 mm/sec, Low: 85 mm/sec
2-772-001 PTr:Std:1st *ENG [0 to 50 / 0 / 2 mm/step]
2-772-002 PTr:Std:2nd *ENG
2-772-003 PTr: Low : 1st *ENG
2-772-004 PTr: Low : 2nd *ENG
2-772-005 SepaDC:Std:1st *ENG
2-772-006 SepaDC:Std:2nd *ENG
2-772-007 SepaDC:Low:1st *ENG
2-772-008 SepaDC:Low:2nd *ENG
Engine SP Mode Tables - SP2000
377