SC9xx: Miscellaneous
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
900 CTL
D
Electric counter error
Abnormal data in the counters.
Defective NVRAM
Defective controller
1. Check the connection between the NVRAM and controller.
2. Replace the NVRAM.
3. Replace the controller.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
990 CTL
D
Software performance error
The software makes an unexpected operation.
Defective software
Defective controller
Software error
1. Turn the main switch off and on.
2. Reinstall the controller and/or engine main firmware.
See Note 1 at the end of the SC table.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
991 CTL
C
Software continuity error
The software has attempted to perform an unexpected operation. However,
unlike SC 990, the object of the error is continuity of the software.
Software program error
Internal parameter incorrect, insufficient working memory.
This SC is not displayed on the operation panel (logging only).