Reference Manual Rev 1.13
Page 118 004R-646-113
19.3.3. Page 0, 1, 2, 3, 7 tokens: Weight Information
These pages hold weight information. The same codes are used for each page.
Code Token
215 (D7
H
) Displayed reading (gross or net)
216 (D8
H
) Gross reading
217 (D9
H
) Net reading
219 (DB
H
) Alternative displayed reading (gross or net)
220 (DC
H
) Alternative gross reading
221 (DD
H
) Alternative net reading
222 (DE
H
) mV/V value
223 (DF
H
) Absolute gross peak reading
224 (E0
H
) Preset tare value
225 (E1
H
) Tare value (tare or preset tare)
226 (E2
H
) Tare label (T or PT)
227 (E3
H
) Unit ID page 0 only
Tracable weight date Page 3 only
Register Header Page 7 only
228 (E4
H
) Ticket end page 0 only
Tracacble weight time Page 3 only
Register Footer Page 7 only
229 (E5
H
)
Status 0: Error, Overload, Underload, Motion, Net, Gross
(Uses last weight sent)
page 0 only
230 (E6
H
)
Status 1: Error, Overload, Underload, Net, Gross (Uses last
weight sent)
page 0 only
231 (E7
H
)
Status 2: Motion, ‘ ‘
page 0 only
232 (E8
H
)
Status 3: Centre of Zero, ‘ ‘
page 0 only
233 (E9
H
)
Status 4: -, Range 1, Range 2 (Uses last weight sent)
page 0 only
234 (EA
H
)
Status 5: C, Motion, ‘ ‘
page 0 only
235 (EB
H
)
Status 6: _N__ Net, _G__ Gross (Uses last weight sent)
page 0 only
236 (EC
H
)
Status 7: Error, Overload, Underload, Motion, Net, Gross
(Uses automatic transmission reading)
page 0 only
237 (ED
H
) Automatic transmit reading page 0 only
238 (EE
H
) Automatic transmit start characters page 0 only
239 (EF
H
) Automatic transmit end characters page 0 only
240 (F0
H
) Weight units page 0 only
241 (F1
H
) Displayed string (primary display) page 0 only
242 (F2
H
) Displayed unit (primary display) page 0 only
243 (F3
H
) Auto Transmit FMT.REG header page 0 only
244 (F4
H
) Auto Transmit FMT.REG weight page 0 only
245 (F5
H
) Auto Transmit FMT.REG status page 0 only
246 (F6
H
) Auto Transmit FMT.REG footer page 0 only
247 (F7
H
) Alternative Tare value page 0 only
248 (F8
H
)
Status 8: Overload, Underload, In range
page 0 only
249 (F9
H
)
Status 9: Motion, Stable
page 0 only
250 (FA
H
)
Status 10: OL over/underload, US unstable, ST stable
page 0 only
251 (FB
H
)
Status 11: Gross, Net
page 0 only
252 (FC
H
) IO status page 0 only
253 (FD
H
) Setpoint status page 0 only
Table 11: Print tokens: weight information
19.3.4. Page 4, 5, 6 tokens: Product Information:
These pages hold product information where: